PURE PARTS – Thermo as the active functional world

PURE THERMO

Thermal function at minimal build-up height.

A thin, applicable coating technology for thermally relevant component areas, complex geometries and applications with limited installation space.

THE CHALLENGE

When installation space becomes a technical constraint.

Limited build-up height

Conventional systems reach structural limits where an additional build-up cannot be accommodated.

Complex geometries

Details and connections cannot always be addressed with a conventional installed solution.

Existing connections

Retrofit solutions must work where existing elements, component boundaries and constructions are already fixed.

Local thermal hotspots

For certain detail problems, targeted local thermal treatment may complement the overall measure.

Hard-to-reach areas

Individual surfaces or details cannot always be addressed with conventional systems without extensive construction work.

WHERE IS IT USED?

Thermal function at critical points.

Reveals & connections
Cold interior surfaces
Existing-building details
Complex geometries
Basement areas
Special technical surfaces after assessment
SYSTEM BUILD-UP

From component to functional layer.

Substrate → PURE THERMO functional layer → defined system layer(s)

The thermal effect results from the interaction of substrate, applied functional layer and the specific component build-up.

PURE THERMO is not designed as generic full thermal insulation, but as a targeted functional layer for thermally relevant areas with limited space and complex boundary conditions.

Detailed system representation for technical inspection.
HOW DOES THE MATERIAL WORK?

The material principle can be explained in a few steps.

Macro: the material structure influences heat transport.

The relevant effect results from the structure of the layer, not from a large material mass.

Within the nanoporous architecture, heat transport through the functional layer is reduced. This allows a very thin coating to be effective for defined thermal applications. The specific effect must always be assessed in the relevant component and system context.

Material structure as the basis of the thermal function.

Technically precise wording

PURE THERMO is a material and coating technology for defined thermal functional areas. Its effect is assessed in a clear system context, not as a general replacement for every build-up.

APPLICATION FIELDS

Typical applications and system contexts.

Existing buildings

Components with limited installation space or existing constraints.

Detail areas

Connections, reveals and complex transitions.

Complex geometries

Functional areas with irregular surfaces and system integration.

Technical surfaces

Thermally relevant areas with a defined testing and system logic.

APPLICATION IN PRACTICE

Historical demonstration and test scenes

The webcut shows a historical surface and heat demonstration followed by a separate burner test on a coated demonstrator. Material application is not shown in this clip.

B · internal development documentation

What you see

  • demonstrator on a heated plate
  • manual surface check
  • preparation of a burner test
  • direct flame on the demonstrator
APPLICATION OVERVIEW

More than insulation alone.

Illustrative overview of potential application scenarios. Technical suitability and the specific system build-up must be assessed for each application and project.
TECHNICAL CORE VALUES

The essential parameters as actual product data.

A – EXTERNALLY TESTED

A · externally tested
Thermal conductivity (λ)0.0335 ± 0.0003 W/(m·K)A · externally testedProduct assignment and stated limitations remain applicable to this value.

B – INTERNALLY DOCUMENTED

B · internally documented
Water-vapour transmission rate (V)25.6 g/(m²·d)B · internally documentedProduct assignment and stated limitations remain applicable to this value.
Water-vapour diffusion-equivalent air-layer thickness (sd)0.76 mB · internally documentedProduct assignment and stated limitations remain applicable to this value.
Consumption0.6 kg/(mm·m²)B · internally documented
Layer thickness per spray passca. 4–6 mm B · internally documentedProduct assignment and stated limitations remain applicable to this value.

C – CALCULATED / MODELLED

C · calculated / modelled
Water-vapour diffusion resistance factor (μ)ca. 95–109; praxisnah etwa 100 C · calculated / modelledProduct assignment and stated limitations remain applicable to this value.
Thermal resistance at 5 mm (R)0.143 m²K/WC · calculated / modelledCalculated using R = d / λ and the model assumption λ = 0.035 W/(m·K). Evidence C; not an additional measured value.
Thermal resistance at 10 mm (R)0.286 m²K/WC · calculated / modelledCalculated using R = d / λ and the model assumption λ = 0.035 W/(m·K). Evidence C; not an additional measured value.
Thermal resistance at 20 mm (R)0.571 m²K/WC · calculated / modelledCalculated using R = d / λ and the model assumption λ = 0.035 W/(m·K). Evidence C; not an additional measured value.
Thermal resistance at 30 mm (R)0.857 m²K/WC · calculated / modelledCalculated using R = d / λ and the model assumption λ = 0.035 W/(m·K). Evidence C; not an additional measured value.
CALCULATED BUILDING-PHYSICS MODEL

What is the calculated thermal effect of PURE THERMO on your building component?

Enter the existing U-value and the desired PURE THERMO layer thickness. The calculator shows the additional thermal resistance and the calculated U-value of the treated building component.

C · calculated / modelledCalculation basis λ = 0.035 W/(m·K)
Additional thermal resistance R PURE THERMO0.286 m²K/W
Existing thermal resistance R0.667 m²K/W
Existing U-value1.500 W/(m²K)
Calculated new U-value1.050 W/(m²K)
Calculated U-value reduction of the treated building component30.0 %
PURE THERMO layer thickness (mm)Calculated U-value (W/(m²K))
Model calculation – Evidence status C

This calculation shows the mathematical change in the thermal transmittance of the treated building component based on the values entered. It does not constitute a general statement on whole-building energy savings, funding eligibility or regulatory compliance. The actual system build-up must be assessed for each project.

The external Kiwa test value of 0.0335 W/(m·K) refers to THERM 4410. Formal assignment to the current PURE THERMO version is documented separately.

B · internally documented

Internal GFRP comparative tests

Historical internal comparative tests examined thermal surface effects and condensation formation on GFRP test specimens with and without a PURE THERMO coating. The results apply exclusively to the documented test setups and do not constitute external certification.

Condensation

In an internal cold-chamber comparison, a GFRP test specimen coated with 10 mm of PURE Thermo showed visibly delayed and reduced condensation compared with the uncoated reference under the documented test conditions.

After 3.5 h: a distinct condensate film on the uncoated reference; low visible condensation on the coated comparison surface.

Cold exposure

In the documented internal comparison, at an external surface temperature around 0 °C, the temperature observed on the coated specimen was approximately 5 °C higher than on the uncoated comparison surface.

Internal test setup · GFRP + PURE Thermo · not transferable to other components.

Heat input

The internal heat comparison documented a mean temperature difference T1–T2 of approximately 38 °C on uncoated GFRP and approximately 60 °C on GFRP coated with 10 mm of PURE Thermo.

Evidence B · internal comparative measurement · not an external performance test.
Open development and test path

From characteristic value to validated application

The following gates describe the intended validation path. They must not be understood as already completed.

Gate 1Formulation / product identity / technical dataopen
Gate 2Thermal conductivity / diffusion / water absorption / adhesion / durabilityopen
Gate 3Route-specific fire and emissions evidenceopen
Gate 4Pilot project and independent monitoringopen
Gate 5External assessment / energy consultants / construction associations / DIBt or ETA route where applicableopen
EXTERNALLY TESTED

λ = 0.0335 W/(m·K)

Kiwa GmbH / MPA Berlin-BrandenburgDIN EN 12664

The evidence for THERM 4410 was determined under documented test conditions according to DIN EN 12664. Key limitations concern assignment of the tested subject to the current PURE THERMO version and transferability to other system build-ups.

APPLICATIONS

PURE THERMO as the basis for different applications.

BASE TECHNOLOGY

PURE THERMO

Shared thermal functional basis for defined system and application routes.

Thermal bridges & details

Application focus for geometrically demanding details and areas with limited build-up height; the system definition is being developed.

B · internally documented
Facade

Exterior route for defined existing mineral façades; the complete exterior and fire evidence package is still being developed.

B · internally documented
Combined functions

Technically plausible combination route requiring testing; no Euroclass before testing and classification of the complete build-up.

D · development status
Interior
B · internally documented
WHERE PURE THERMO IS USEFUL – AND WHERE IT IS NOT

Limitations are part of technical credibility.

Where PURE THERMO plays to its strengths

  • limited build-up height
  • detail areas
  • complex geometries
  • local thermal functions
  • existing connections

What cannot be derived generally

  • No general statement that PURE THERMO replaces conventional insulation systems.
  • No general energy-saving percentages.
  • No general payback statements.
  • No general fire classification for PURE THERMO + PURE FIRE before complete system testing.
  • No general funding eligibility statement.
  • No general mould-prevention claim.
  • No unsupported sound-insulation, recycling or circular-economy claims.
ECONOMICS

Beyond material cost alone.

Economics can comprise material, installation, intervention depth and lifecycle – a qualitative logic where no robust project calculation is available.
FAQ

Frequently asked questions about PURE THERMO.

Can PURE THERMO replace a conventional external thermal insulation composite system?

Not generally. Suitability depends on the component, the required energy-performance target, layer thickness and the approved system build-up.

Is PURE THERMO eligible for KfW funding?

No general KfW product approval is claimed. Funding eligibility depends on the project, measure and evidence provided.

Has the lambda value been externally tested?

For THERM 4410, a thermal conductivity of 0.0335 ± 0.0003 W/(m·K) was externally determined according to DIN EN 12664:2001-05. Assignment to the current PURE THERMO formulation still has to be documented clearly.

Does PURE THERMO prevent mould?

No general mould-prevention claim is approved. Surface temperature, moisture and structural causes must be assessed for each project.