Testing & Evidence

PURE separates external testing, internal documentation, model calculation and development status clearly.

A · externally tested

Externally tested results with a defined test subject and documented conditions.

B · internally documented

Traceable internal documentation, project documentation or documented technical source.

C · calculated / modelled

Calculated or modelled values with transparent assumptions and limits.

D · development status

Development status, planned test path or technical hypothesis without a finished performance claim.

FLAGSHIP DOSSIER

Kiwa / THERM 4410

Externally tested specimen with a clear product-assignment boundary.

B · internally documented

Water vapour / building physics

V = 25.6 g/(m²·d)sd = 0.76 mV2 / mediumμ ≈ 95–109 derived

Documented measurements on sample plates at approximately 7–8 mm. The μ value is derived from sd and layer thickness and was not measured directly.

Documented measured value – original test basis / product assignment under review.
A · externally tested

Efectis: individual test of itHeatProtect 4130

Tested build-up: 5 mm itHeatProtect 4130 on 2.0 mm steel sheet · EN ISO 11925-2.

Small flame

Maximum flame height 50–60 mm · 150 mm mark not reached · no afterflame · no ignition of the filter paper · no burning droplets/particles.

Indicative SBI values

FIGRA 885 / 950 W/s · THR600s 8.13 / 9.70 MJ

No official overall SBI classification results from the indicative test. Results apply exclusively to the tested build-up.
Values & test paths

More than lambda.

The hub prepares the key evidence areas for product and system assessment.

A · externally tested

Thermal conductivity / THERM 4410

Source / test basis: Kiwa GmbH / MPA Berlin-Brandenburg · DIN EN 12664

λ = 0.0335 W/(m·K) under documented test conditions.

Limit: Test subject THERM 4410; formal assignment to the current Pure Thermo version is documented separately.View details
B · internally documented

Water vapour diffusion

Source / test basis: Documented measured value · original test basis under review

V = 25.6 g/(m²·d), sd = 0.76 m, V2 - medium at approx. 7-8 mm test layer.

Limit: Original test basis and product assignment under review. μ approx. 95-109 is derived, not directly measured.View details
C · calculated / modelled

Thermal resistance / U-value model calculation

Source / test basis: Calculation model from layer thickness and λ

Interactive calculator for the calculated component U-value of the treated area.

Limit: Component U-value is not whole-building energy savings.View details
10 mm1.05 W/(m²K)
B · internally documented

Internal temperature comparison

Source / test basis: Internal development documentation

Temperature comparison as documented development and plausibility evidence.

Limit: Does not replace project-specific building-physics assessment.View details
A · externally tested

PURE THERMO individual fire test

Source / test basis: External individual test / defined test build-up

Individual test applies only to the tested build-up.

Limit: Do not derive a general fire classification.View details
A · externally tested

PURE FIRE individual SBI test

Source / test basis: External individual test / defined test build-up

SBI results belong to the tested configuration.

Limit: Tested build-up only; no transfer to the combination.View details
D · development status

PURE THERMO + PURE FIRE test route

Source / test basis: Systemdefinition → EN ISO 11925-2 → EN 13823 / SBI → EN 13501-1

Combination route as development and validation path.

Limit: No combination class without complete system testing and classification.View details
Next step

View technical documents or request project assessment.

For real components, the system context is decisive: substrate, moisture, layer build-up, finish and application limit.